Citizen Systems Network Router 1.8 User Manual Page 47

  • Download
  • Add to my manuals
  • Print
  • Page
    / 61
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 46
CITIZEN OPOS DRIVER 1.8 Application Development Guide
47
OutPutID Property/ OutputCompleteEvent Event
Identifier of asynchronous output started just before is retained and incremented by +1 with the
following output.
<Visual Basic installation example: Output subroutine>
Dim i as Integer
Dim Result As Long
Dim PrintStation As Long
For i = 0 to 10
DoEvents
Result = OPOSPrinter.PrintNormal(PrintStation, "TEST PRINT" + Str(i) + Chr$(&HD) + Chr$(&HA))
Next i
<Visual Basic installation example: Event acquisition subroutine>
Private Sub OPOSPrinter_OutputCompleteEvent(ByVal OutputID As Long)
Debug.Print "OutputCompleteEvent -> " + Str(OutputID)
End Sub
<Output result>
OutputCompleteEvent -> 1
OutputCompleteEvent -> 2
OutputCompleteEvent -> 3
OutputCompleteEvent -> 4
OutputCompleteEvent -> 5
OutputCompleteEvent -> 6
OutputCompleteEvent -> 7
OutputCompleteEvent -> 8
OutputCompleteEvent -> 9
OutputCompleteEvent -> 10
OutputCompleteEvent -> 11
CapRecEmptySensor/ RecEmpty Property
When "Active Paper Sensor” is set to “PaperNearEnd” (Registry: "PaperSensor"="001"), Paper
Out sensor becomes non-active state. Accordingly, the value of the CapRecEmptySensor
property is set to “FALSE” and the value of the RecEmpty property remains in the “FALSE “state
even in the Paper End condition. Here, StatusUpdateEvents (PTR_SUE_REC_EMPTY) is not
reported.
(Configuration Utility)